Secured Trading Service

High Purity Deionized Machine RO Machine Pure Water Machine

Molewater System Co., Ltd.
  • Audited Supplier
  • 10 yrs

Product Specifications

MOLPW-3000

Contact Supplier

Product Highlights

  • Advanced RO+EDI Technology: Integrates Reverse Osmosis and Electrodeionization for ultra-pure water exceeding pharmacopoeia standards.
  • Intelligent PLC Control: Features PLC+HMI system with automatic/manual modes and real-time quality monitoring algorithms.
  • Modular Sanitary Design: Uses pharmaceutical-grade stainless steel/UPVC with dead-leg-free piping to prevent microbial growth.
  • Multi-Layer Safety Protection: Includes alarms, self-diagnosis, pressure relief, and abnormal water quality alerts for safe operation.
  • Energy-Efficient Operation: Smart optimization reduces energy consumption by up to 30% and lowers operational costs via EDI.
  • High Recovery Rate: Recycles concentrated water from RO and EDI to increase total system recovery rate efficiently.
  • Comprehensive Monitoring: Online monitoring of conductivity, TOC, and microbiological counts to ensure strict quality compliance.
  • Turn-Key Solution: Provides full service from technical design and production to shipping, installation, and training.

Shipping

Shipping Cost:
Contact the supplier about freight and estimated delivery time.

Online Trading Protection

Payment Guarantee
T/T PayPal ApplePay GooglePay visa mastercard american express discover JCB diners club PIX SPEI OXXO PSE OZOW Platform-protected payments with refund support for eligible order issues.
Platform Logistics
Clearer shipment tracking with platform-supported logistics.
Inspection Service
Optional pre-shipment inspection for quality and quantity checks.
After-Sales & Dispute Handling
Platform-assisted dispute resolution, including refunds or returns when applicable.

Only orders placed and paid through Made-in-China.com Secured Trading are eligible for payment protection and the corresponding platform services.

Product Images of High Purity Deionized Machine RO Machine Pure Water Machine

High Purity Deionized Machine RO Machine Pure Water Machine
High Purity Deionized Machine RO Machine Pure Water Machine pictures & photos
High Purity Deionized Machine RO Machine Pure Water Machine
High Purity Deionized Machine RO Machine Pure Water Machine pictures & photos
High Purity Deionized Machine RO Machine Pure Water Machine
High Purity Deionized Machine RO Machine Pure Water Machine pictures & photos
High Purity Deionized Machine RO Machine Pure Water Machine
High Purity Deionized Machine RO Machine Pure Water Machine pictures & photos
High Purity Deionized Machine RO Machine Pure Water Machine
High Purity Deionized Machine RO Machine Pure Water Machine pictures & photos
High Purity Deionized Machine RO Machine Pure Water Machine
High Purity Deionized Machine RO Machine Pure Water Machine pictures & photos
High Purity Deionized Machine RO Machine Pure Water Machine
  • High Purity Deionized Machine RO Machine Pure Water Machine
  • High Purity Deionized Machine RO Machine Pure Water Machine
    High Purity Deionized Machine RO Machine Pure Water Machine
  • High Purity Deionized Machine RO Machine Pure Water Machine
    High Purity Deionized Machine RO Machine Pure Water Machine
  • High Purity Deionized Machine RO Machine Pure Water Machine
    High Purity Deionized Machine RO Machine Pure Water Machine
  • High Purity Deionized Machine RO Machine Pure Water Machine
    High Purity Deionized Machine RO Machine Pure Water Machine
  • High Purity Deionized Machine RO Machine Pure Water Machine
    High Purity Deionized Machine RO Machine Pure Water Machine
  • High Purity Deionized Machine RO Machine Pure Water Machine
    High Purity Deionized Machine RO Machine Pure Water Machine

Find Similar Products

Product Description

High Purity Deionized Machine RO Machine Pure Water Machine
Product Description
Pharmaceutical purified water system, WFI multi-effect distiller for injection, PSG pure steam generator
 
We provide turn-key solution for your pharamceutical water system project. From technical design to machine production, shipping, installation and training.
 
Specification
No.
Unit
Parameter information
1
Name
Molecular 3000L/H PW System
2
Model
MOLPW-3000L
3
Permeate capacity
3000L/H@ 25℃
4
Feed water
Tap water
5
Pure water quality
Electrical Conductivity <1.3μs/cm,meet GMP, EP/USP
6
Technology
double stages reverse osmosis unit+EDI unit
7
Control method
Automatic Control (manually also available)
Functional Advantages
High Purity Deionized Machine RO Machine Pure Water Machine
ADVANCED PURIFICATION TECHNOLOGY
 
Our pharmaceutical water systems integrate cutting-edge Reverse Osmosis (RO) and Electrodeionization (EDI) technology to consistently produce ultra-pure water that exceeds pharmacopoeia requirements with a built-in safety margin.
INTELLIGENT AUTOMATION & REAL-TIME QUALITY CONTROL
 
Equipped with a PLC+HMI control system, the equipment features both automatic and manual operation modes with comprehensive real-time monitoring. Continuous water quality while intelligent algorithms optimize operational parameters to maximize efficiency and minimize downtime.
High Purity Deionized Machine RO Machine Pure Water Machine
High Purity Deionized Machine RO Machine Pure Water Machine
MODULAR & SANITARY DESIGN FOR EASY VALIDATION
 
The modular construction simplifies installation, maintenance, and future capacity expansion. All water-contact components are manufactured from pharmaceutical-grade stainless steel or UPVC, featuring sloped piping and a dead-leg-free design to prevent microbial growth.
MULTI-LAYER SAFETY PROTECTION SYSTEM
 
Comprehensive safety features include multiple alarm systems, self-diagnostic functions, pressure relief valves, high/low-level protection, and abnormal water quality alerts. This redundant protection architecture ensures continuous safe operation and protects your critical pharmaceutical processes from contamination risks.
High Purity Deionized Machine RO Machine Pure Water Machine
High Purity Deionized Machine RO Machine Pure Water Machine
ENERGY-EFFICIENT & COST-EFFECTIVE OPERATION
 
Smart operational optimization reduces energy consumption by up to 30% compared to conventional systems. The EDI module lowers operational costs while minimizing environmental impact. Durable core components offer extended service life with minimal maintenance requirements.
Features
 Raw water treatment system
Pasteurization is applied to the pretreatment filter
Three-stage pretreatment ensures the removal of large particles, impurities and colored substances in the raw water, meeting the feed water requirements for reverse osmosis
Reverse osmosis +EDI system
Energy-saving design
The concentrated water from the first-level RO can be recycled back to the raw water tank (recovery rate ≤30%).
The EDI concentrated water is returned to the RO feed water (to increase the total recovery rate of the system).
Water quality monitoring point
The conductivity of RO product water (standard value ≤5 μS/cm).
The conductivity of the EDI produced water (standard value ≤1μS/cm, 25℃).
Online monitoring of total organic carbon (TOC) in the purified water tank (Pharmacopoeia requirement: ≤500 ppb).
 Purified water distribution system
 Pasteurization is applied to the PW distribution system
Company Profile
High Purity Deionized Machine RO Machine Pure Water Machine
High Purity Deionized Machine RO Machine Pure Water Machine
High Purity Deionized Machine RO Machine Pure Water Machine
FAQ
Q: What is the typical process flow of a pharmaceutical purified water system? 
A: A typical PW system usually includes pretreatment (multimedia filtration, activated carbon, softener), reverse osmosis (RO), electrodeionization (EDI), storage, and distribution loop with constant circulation and UV / ozone sanitization.

 
Q: Why is EDI commonly used instead of mixed bed ion exchange in modern PW systems? 
A: EDI avoids chemical regeneration, reduces chemical contamination risk, ensures stable water quality, and is more compliant with GMP requirements for continuous and reliable production.
 
Q: What key quality parameters must be monitored for purified water in pharmaceuticals? 
A: Key parameters include conductivity, TOC, microbiological count, endotoxins (if for WFI preparation), pH, hardness, and heavy metals, in accordance with pharmacopeial standards such as USP, EP, or ChP.
 
Q: What is the difference between Purified Water (PW) and Water for Injection (WFI)? 
A: PW is produced by RO/EDI and used for non-parenteral products. WFI has stricter limits for endotoxins and microbes, usually produced by distillation or multiple-effect evaporation from purified water.
 
Q: How to control microbial growth in the purified water distribution loop? 
A: Maintain continuous circulation at a certain flow rate, control loop temperature (hot water sanitization), regularly sanitize with heat or chemical agents, install UV sterilizers, and avoid dead legs.

About the Supplier

This supplier has been audited by TÜV Rheinland. Verify the report on the official TÜV Rheinland website with ID "MIC-ASI269130". Items marked "verified" are certified.

Watch Video
Watch Video
Molewater System Co., Ltd.
Molewater System Co., Ltd.
Molewater System Co., Ltd.
Molewater System Co., Ltd.
Molewater System Co., Ltd.
Molewater System Co., Ltd.
Molewater System Co., Ltd.
Molewater System Co., Ltd.

About Our Factory & Business Background

verified Business Type
Manufacturer/Factory & Trading Company
Address
No. 29, Baihai Road, Baishiyi, High Tech District, Chongqing, China
verified Plant Area
17455 square meters
verified Number of Employees
178
verified Registered Capital
100,880,000 RMB
verified Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
verified International Commercial Terms(Incoterms)
FOB, CIF, CFR, EXW
verified Average Lead Time
Peak Season Lead Time: one month
Off Season Lead Time: within 15 workdays
verified Nearest Port
Shanghai Port; Chongqing Port
verified Minimum Order Quantity
1
verified Supply Chain Partners
244

Our Production Capability & Technical Expertise

verified Main Products
Water Treatment System
verified Production Lines
3
verified Production Machines
Cutting Machine, Cutting Machine, Polishing Machine, Rolling Machine, Welding Machine
verified QA/QC inspectors
6 people
verified Inspection Type for Finished Products
100% inspection(Visual inspection & Function inspection)
verified Inspection Method for Finished Products
Have instructions and uniformly followed
verified Customization Options
Customization from Samples, Customization from Designs, Full Customization, Minor Customization, Flexible customization
verified ODM Service Available
Yes
verified OEM Service Available
Yes
verified R&D Engineers
20 people
verified Traceability of Raw Materials
Yes
verified Own Brand
Yes

Our Industry Experience & Global Business Record

verified Year of Establishment
2003-02-24
verified Export Year
10 Years
verified Main Markets
Europe
verified Repeat Buyers Choice
50%~80%
verified Annual Export Revenue
2,069,834 RMB
verified Number of Foreign Trading Staff
7
verified Overseas Agent/Branch
Yes
verified New Products Launched in Last year
Yes

Our Certifications, Standards & Industry Recognition

verified Management System Certification
ISO9001:2015, Others
verified Product Certification
RoHS, CE
verified Cooperated with Fortune 500
No

FAQ

What is the typical process flow of a pharmaceutical purified water system?
A typical PW system usually includes pretreatment (multimedia filtration, activated carbon, softener), reverse osmosis (RO), electrodeionization (EDI), storage, and distribution loop with constant circulation and UV / ozone sanitization.
Why is EDI commonly used instead of mixed bed ion exchange in modern PW systems?
EDI avoids chemical regeneration, reduces chemical contamination risk, ensures stable water quality, and is more compliant with GMP requirements for continuous and reliable production.
What key quality parameters must be monitored for purified water in pharmaceuticals?
Key parameters include conductivity, TOC, microbiological count, endotoxins (if for WFI preparation), pH, hardness, and heavy metals, in accordance with pharmacopeial standards such as USP, EP, or ChP.
What is the difference between Purified Water (PW) and Water for Injection (WFI)?
PW is produced by RO/EDI and used for non-parenteral products. WFI has stricter limits for endotoxins and microbes, usually produced by distillation or multiple-effect evaporation from purified water.
How to control microbial growth in the purified water distribution loop?
Maintain continuous circulation at a certain flow rate, control loop temperature (hot water sanitization), regularly sanitize with heat or chemical agents, install UV sterilizers, and avoid dead legs.
What materials are used for water-contact components?
All water-contact components are manufactured from pharmaceutical-grade stainless steel (SS304+SS316L) or UPVC.

Send your message to this supplier